#
296425 |
|
06-Mar-2016 |
kp |
MFC r295836: ifconfig(8): can't use 'name' or 'description' when creating interface with auto numbering
If one does 'ifconfig tap create name blah', it will return error because the 'name' command doesn't properly populate the request sent to ioctl(...). The 'description' command has the same bug, and is also fixed with this patch.
If one does 'ifconfig tap create mtu 9000 name blah', it DOES work, but 'tap0' (or other sequence number) is echoed, instead of the expected 'blah'. (assuming the name change actually succeeded)
PR: 206876 Submitted by: Marie Helene Kvello-Aune <marieheleneka@gmail.com> Differential Revision: https://reviews.freebsd.org/D5341
|
#
286810 |
|
15-Aug-2015 |
melifaro |
MFC r270064,r270068,r270069,r270115,r270129,r270287,r270822,r271014, r271524,r273541,r282967,r283009,r283364.
Add support for reading i2c SFP/SFP+ data from NIC driver and presenting most interesting fields via ifconfig -v. This version supports Intel ixgbe driver only.
Tested on: Cisco,Intel,Mellanox,ModuleTech,Molex transceivers
* Add new net/sff8436.h containing constants used to access QSFP+ data via i2c inteface. These constants has been taken from SFF-8436 "QSFP+ 10 Gbs 4X PLUGGABLE TRANSCEIVER" standard rev 4.8. * Add support for printing QSFP+ information from 40G NICs such as Chelsio T5.
Example: cxl1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=ec07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,.....> ether 00:07:43:28:ad:08 nd6 options=29<PERFORMNUD,IFDISABLED,AUTO_LINKLOCAL> media: Ethernet 40Gbase-LR4 <full-duplex> status: active plugged: QSFP+ 40GBASE-LR4 (MPO Parallel Optic) vendor: OEM PN: OP-QSFP-40G-LR4 SN: 20140318001 DATE: 2014-03-18 module temperature: 64.06 C voltage: 3.26 Volts lane 1: RX: 0.47 mW (-3.21 dBm) TX: 2.78 mW (4.46 dBm) lane 2: RX: 0.20 mW (-6.94 dBm) TX: 2.80 mW (4.47 dBm) lane 3: RX: 0.18 mW (-7.38 dBm) TX: 2.79 mW (4.47 dBm) lane 4: RX: 0.90 mW (-0.45 dBm) TX: 2.80 mW (4.48 dBm)
Tested on: Chelsio T5 Tested on: Mellanox/Huawei passive/active cables/transceivers.
Sponsored by: Yandex LLC
|
#
286810 |
|
15-Aug-2015 |
melifaro |
MFC r270064,r270068,r270069,r270115,r270129,r270287,r270822,r271014, r271524,r273541,r282967,r283009,r283364.
Add support for reading i2c SFP/SFP+ data from NIC driver and presenting most interesting fields via ifconfig -v. This version supports Intel ixgbe driver only.
Tested on: Cisco,Intel,Mellanox,ModuleTech,Molex transceivers
* Add new net/sff8436.h containing constants used to access QSFP+ data via i2c inteface. These constants has been taken from SFF-8436 "QSFP+ 10 Gbs 4X PLUGGABLE TRANSCEIVER" standard rev 4.8. * Add support for printing QSFP+ information from 40G NICs such as Chelsio T5.
Example: cxl1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=ec07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,.....> ether 00:07:43:28:ad:08 nd6 options=29<PERFORMNUD,IFDISABLED,AUTO_LINKLOCAL> media: Ethernet 40Gbase-LR4 <full-duplex> status: active plugged: QSFP+ 40GBASE-LR4 (MPO Parallel Optic) vendor: OEM PN: OP-QSFP-40G-LR4 SN: 20140318001 DATE: 2014-03-18 module temperature: 64.06 C voltage: 3.26 Volts lane 1: RX: 0.47 mW (-3.21 dBm) TX: 2.78 mW (4.46 dBm) lane 2: RX: 0.20 mW (-6.94 dBm) TX: 2.80 mW (4.47 dBm) lane 3: RX: 0.18 mW (-7.38 dBm) TX: 2.79 mW (4.47 dBm) lane 4: RX: 0.90 mW (-0.45 dBm) TX: 2.80 mW (4.48 dBm)
Tested on: Chelsio T5 Tested on: Mellanox/Huawei passive/active cables/transceivers.
Sponsored by: Yandex LLC
|